TECHNICAL TEST REPORT OF JOLLY BITULEX EXPANSION JOINT FILLER
TEST AS PER ASTM D175125 MM THICK 35% BITUMENCONTENT
1. Dimension Thickness (mm)25 MM
2. Compression
a. Stress applied for compressing specimen to 50% of its thickness2800 - 3200 KPa
b. Loss in Weight after application of Stress0.1 - 0.2%
3. Extrusion (mm) After compressing to 50% of the specimen's thickness0.5 mm
4. Recovery(%) 10 minutes after compressing to 50% of the specimen's thickness75 - 80%
5.Density (kg/m3)330 - 350
6. Water absorption(%)15%
7. Asphalt content(%)36 - 37%